QIAGEN artus CMV RGQ MDx Kit
Ready-to-use kit for real-time PCR quantitation of cytomegalovirus (CMV) DNA in EDTA plasma on the Rotor-Gene Q MDx, with quantifiable results as low…
GMP-manufactured primers and probes for BK virus, EBV, HSV-1/HSV-2 and VZV targets, designed for rapid results on real-time PCR instruments.
QIAGEN Analyte-Specific Reagents (ASR) are easy-to-use primers and probes for laboratories setting up their own real-time PCR tests. Every ASR is manufactured according to GMP and released in accordance with QIAGEN quality control and quality assurance procedures to ensure a consistent product.
The reagents are designed for rapid results on real-time PCR instruments such as the Rotor-Gene Q MDx. The range comprises separate primer and probe reagents for BK virus, Epstein-Barr virus (EBV), herpes simplex virus (HSV-1, HSV-2) and varicella zoster virus (VZV) targets.
| Cat. no. | Description | Pack size |
|---|---|---|
| 1067391 | BK Virus Primer ASR – amplification of a 274 bp region covering parts of the VP2 and VP3 genes | (24) |
| 1067392 | BK Virus Probe ASR – detection of the 274 bp VP2/VP3 region | (24) |
| 1083003 | Epstein-Barr Virus (EBV) Primer ASR – amplification of a 97 bp region of the EBNA-1 gene | — |
| 1083005 | Epstein-Barr Virus (EBV) Probe ASR – detection of the 97 bp EBNA-1 region | — |
| 1066150 | HSV Primer ASR – amplification of a 154 bp region of the UL5 gene of HSV-1 or HSV-2 | (24) |
| 1066155 | HSV-1 Probe ASR – detection of the 154 bp UL5 region of HSV-1 | (24) |
| 1066160 | HSV-2 Probe ASR – detection of the 154 bp UL5 region of HSV-2 | (24) |
| 1067287 | VZV Primer ASR – amplification of an 82 bp region of the ORF38 gene | (24) |
| 1067291 | VZV Probe ASR – detection of the 82 bp ORF38 region | (24) |
| Manufacturer | QIAGEN |
|---|---|
| Product type | Reagent (primers and probes) |
| Technology | Real-time PCR |
| Targets | BK virus (VP2/VP3), EBV (EBNA-1), HSV-1 and HSV-2 (UL5), VZV (ORF38) |
| Manufacturing | According to GMP |
| Compatible system | Real-time PCR instruments such as Rotor-Gene Q MDx |