Drugs of Abuse (DoA) and Therapeutic Drug Monitoring (TDM) Tests

Thermo Scientific CEDIA™ Oral Fluid Drugs of Abuse Calibrators and Controls

Brand: Thermo Scientific Product code: 10014957

Ready-to-use CEDIA™ negative and cutoff calibrators and low/high control sets for oral fluid testing of amphetamine, cocaine, opiates, phencyclidine and methamphetamine.

Available to order
  • Installation and user training support
  • Technical service and preventive maintenance
  • Fast, transparent quotation process

Thermo Scientific CEDIA™ Oral Fluid Drugs of Abuse Calibrators and Controls are ready-to-use products for the calibration and quality control of CEDIA drugs of abuse assays performed on oral fluid samples. They eliminate time-consuming preparation steps while supporting high analytical accuracy, with applications for an array of clinical chemistry analyzers.

The range includes multi-analyte negative and cutoff calibrators and a low/high control set for amphetamine, cocaine, opiates and phencyclidine, as well as separate negative and cutoff calibrators and a control set for methamphetamine; concentrations are listed in the table below.

Key features

  • Ready-to-use calibrators and controls
  • Qualitative or semi-quantitative result options
  • Excellent correlation to GC/MS
  • Applications for an array of clinical chemistry analyzers
  • Variety of calibrators and multiconstituent control sets

Ordering options

Cat. no.DescriptionPack size
10014957Control set, low/high – amphetamine 25/75, cocaine 2.5/7.5, opiates 5/15, phencyclidine 0.5/1.5 ng/mL2 x 15 mL
10014954Negative calibrator – amphetamine, cocaine, opiates, phencyclidine (0 ng/mL)1 x 20 mL
10014955Cutoff calibrator – amphetamine 50, cocaine 5, opiates 10, phencyclidine 1 ng/mL1 x 10 mL
10014950Methamphetamine negative calibrator (0 ng/mL)1 x 10 mL
10014951Methamphetamine cutoff calibrator (40 ng/mL)1 x 5 mL
10014953Methamphetamine control set, low/high (20/60 ng/mL)2 x 10 mL

Related products

Drugs of Abuse (DoA) and Therapeutic Drug Monitoring (TDM) Tests

Thermo Scientific β-Glucuronidase Enzyme

Hydrolysis enzyme used with the CEDIA™ Benzodiazepine Assay to hydrolyze glucuronide metabolites and enhance parent-drug detection sensitivity; 1 x 5…

Price on request
Drugs of Abuse (DoA) and Therapeutic Drug Monitoring (TDM) Tests

Thermo Scientific CEDIA™ LSD Drugs of Abuse Assays

CEDIA™ cloned enzyme donor homogeneous immunoassay for detecting LSD in urine samples on clinical chemistry analyzers, with qualitative or…

Price on request
Drugs of Abuse (DoA) and Therapeutic Drug Monitoring (TDM) Tests

Thermo Scientific DRI™ Cocaine Drugs of Abuse Assays

Liquid, ready-to-use DRI™ homogeneous enzyme immunoassay for detecting the cocaine metabolite benzoylecgonine in urine samples on clinical chemistry…

Price on request
Drugs of Abuse (DoA) and Therapeutic Drug Monitoring (TDM) Tests

Thermo Scientific CEDIA™ Benzodiazepine Assays

CEDIA™ cloned enzyme donor homogeneous immunoassay for detecting benzodiazepines in urine samples on clinical chemistry analyzers, with qualitative…

Price on request
Drugs of Abuse (DoA) and Therapeutic Drug Monitoring (TDM) Tests

Thermo Scientific CEDIA™ Methadone Drugs of Abuse Assays

CEDIA™ cloned enzyme donor homogeneous immunoassay for detecting methadone (MTD) in urine samples on clinical chemistry analyzers, with qualitative…

Price on request